Out Of Stock
Notify me when its in stock|
Basic |
|
|
Series |
Powerlogic |
|
Product Name |
Powerlogic Pm3000 |
|
Product Group |
Pm5340 |
|
Product or Component Type |
Power meter |
|
Characteristic |
|
|
Overvoltage Category |
III |
|
Relative Humidity |
5-95 % -De 50-50 °C |
|
Environmental Characteristic for Storage |
-25-70 °C |
|
Operational Altitude |
0…3000 M |
|
Environmental Characteristic for Storage |
-40-85 °C |
|
Electromagnetic Compatibility |
1,2/50 µs Shock Waves Immunity Test Level 4 'E conforming to IEC 61000-4-5 |
|
Electrical Fast Transient Burst Immunity Test Level 4 'E conforming to IEC 61000-4-4 |
|
|
Susceptibility To Electromagnetic Fields Level 3 'E conforming to IEC 61000-4-3 |
|
|
Conducted RF disturbances Level 3 'E Conforming to IEC 61000-4-6 |
|
|
Conducted and radiated emissions Class B 'E Conforming to EN 55022 |
|
|
IP Protection Degree |
Body: Ip30 'E Conforming to IEC 60529 |
|
Front: Ip52 'E Conforming to IEC 60529 |
|
|
Pollution Degree |
2 |
|
Compatibility Code |
Pm5340 |
|
General Features |
|
|
[Us] Rated Supply Voltage |
100...277 V Ac 45...65 Hz |
|
100…300 V Dc |
|
|
Analog Entrance Voltage |
Current 0…1A |
|
Current 0…5A |
|
|
Memory Capacity |
256 Kb |
|
Device Application |
Sub Billing |
|
Multi-Tariff |
|
|
Power Monitoring |
|
|
Number of Output |
2 Digital |
|
2 Relay |
|
|
Depth |
70 Mm |
|
Accuracy Class |
Class 0.5S Active Energy 'E Conforming to IEC 62053-22 |
|
|
Class 1 Active Energy 'E Conforming to IEC 62053-21 |
|
|
Class 2 Rective Energy 'E Conforming to IEC 62053-23 |
|
|
Class C Active Energy 'E Conforming to EN 62053-3 |
|
Screen Resolution |
128 X 128 Pixel |
|
Screen Type |
Backlighted LCD |
|
Frequency Measuring Range |
45-65 Hz |
|
Width |
90 Mm |
|
Number of Input |
2 Digital |
|
Displayed Information |
Tariff (4) |
|
Power Quality Analyse |
Until 15th Harmonic |
|
Support of Port Communication |
Rs485 |
|
Protocol of Port Communication |
Bacnet Ip |
|
Modbus Tcp/Ip -De 10, 100 Mbit/Sn, Isolation 2500 V |
|
|
Pole Description |
1P + N |
|
3P |
|
|
3P + N |
|
|
Montage Support |
Block |
|
Montage Type |
Flush Mounted Montage |
|
Rated Current (Ir) |
0,0416666666666667 |
|
0,208333333333333 |
|
|
Measuring Current |
0.02-1.2 A |
|
0.05-6 A |
|
|
Measuring Accuracy |
Current % 0,3 0,5...6 A |
|
Current % 0,5 0,1...1,2 A |
|
|
Voltage % 0,3 50...330 V |
|
|
Voltage % 0,3 80...570 V |
|
|
Measuring Voltage |
50-330 V Ac 45...65 Hz Directly |
|
50-330 V Ac 45...65 Hz from Phase to Neutral |
|
|
|
570-999000 V Ac 45...65 Hz with External VT |
|
|
80-570 V Ac 45...65 Hz Directly |
|
|
80-570 V Ac 45...65 Hz Phase- Phase |
|
Measuring Type |
Current |
|
Active and Reactive Power |
|
|
Energy |
|
|
Frequency |
|
|
Voltage |
|
|
Visible Power |
|
|
Power Factor |
|
|
Total Current Harmonic Distortion Thd (I) |
|
|
Total Voltage Harmonic Distortion Thd (U) |
|
|
Sampling Speed |
32 Sample per Loop |
|
Marketing Segment |
House |
|
Small-Size Enterprises |
|
|
Standards |
En 50470-1 |
|
En 50470-3 |
|
|
IEC 60529 |
|
|
IEC 61557-12 |
|
|
IEC 62053-22 |
|
|
IEC 62053-24 |
|
|
Ul 61010-1 |
|
|
Network Frequency |
50 Hz |
|
60 Hz |
|
|
Product Weight |
0.26 G |
|
Product Certificates |
Ce 'E Conforming to IEC 61010-1 |
|
Culus 'E Conforming to uı 61010-1 |
|
|
UI |
|
|
Power Consumption in Va |
5Va |
|
Data Recording |
5 Alarm |
|
Minimum - Maximum of Instantaneous Value |
|
|
Time Stamp |
|
|
Local Signalling |
100 Ms 230 V Ac Typical |
|
100 Ms 415 V Ac Typical |
|
|
80 Ms 120 V Ac Typical |
|
|
Height |
95 Mm |