[Icw] Rated Short-Time Withstand Current

100 A - 1 S for Signaling Circuit

105 A -De <40 °C - 10 S For Power Circuit

120 A - 500 Ms for Signaling Circuit

140 A - 100 Ms For Signaling Circuit

210 A -De <40 °C - 1 S For Power Circuit

30 A -De <40 °C - 10 Min For Power Circuit

61 A -De <40 °C - 1 Min For Power Circuit

[Ie] Rated Operational Voltage

25 A 60 °C) -De <= 440 V Ac Ac-1 For Power Circuit

9 A 60 °C) -De <= 440 V Ac Ac-3 For Power Circuit

[Ith] Classic Open Air Thermic Current

10 A -De <60 °C For Signaling Circuit

25 A -De <60 °C For Power Circuit

[Ue] Rated Operational Voltage

Power Circuit: <= 300 V Dc

Power Circuit: <= 690 V Ac 25...400 Hz

[Ui] Rated Insulation Voltage

Power Circuit: 600 V Csa certificated

Power Circuit: 600 V Ul certificated

Power Circuit: 690 V 'E Conforming to ıec 60947-4-1

Signaling Circuit: 600 V Csa certificated

Signaling Circuit: 600 V Ul certificated

Signaling Circuit: 690 V 'E Conforming toıec 60947-1

[Uimp] Rated Impulse Withstand Voltage

6 Kv 'E Conforming toıec 60947

Overvoltage Category

Iıı

Terminals

Power Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm²flexible 

Power Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm²flexible Cable Jagless

Power Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm²Solid Cable Jagless

Power Circuit: Screw Clamp Terminals 2 Cable(s) 1-2.5 Mm²flexible 

Power Circuit: Screw Clamp Terminals 2 Cable(s) 1-4 Mm²flexible Cable Jagless

Power Circuit: Screw Clamp Terminals 2 Cable(s) 1-4 Mm²Solid Cable Jagless

Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm²flexible 

Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm²flexible Cable Jagless

Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm²Solid Cable Jagless

Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-2.5 Mm²flexible 

Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-4 Mm²flexible Cable Jagless

Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-4 Mm²Solid Cable Jagless

Operating Time

65,45...88,55 Msn Closing

20...30 Msn Opening

Electric Durability

0.6 Mcycles 25 A Ac-1 Ue'De <= 440 V

2 Mcycles 9 A Ac-3 Ue'De <= 440 V

Level of Reliability Safety 

B10D = 1369863 Cycles Rated Load Contactor 'E Conforming to En/Iso 13849-1

B10D = 20000000 Cycles Mechanical Load Contactor 'E Conforming to En/Iso 13849-1

Irms Rated Closing Capacity

For 140 A Ac Signaling Circuit 'E Conforming to Iec 60947-5-1

For 250 A Dc Signaling Circuit 'E Conforming to Iec 60947-5-1

For 250 A -De 440 V Power Circuit 'E Conforming to Iec 60947

Fuse Value

For 10 A Gg Signaling Circuit 'E Conforming to Iec 60947-5-1

For Coordination Type 2 20 A Gg -De <= 690 V Power Circuit

For Coordination Type 1 25 A Gg -De <= 690 V Power Circuit

Contactor Application

Resistor Load

Motor Control

Control Circuit Voltage

24 V Dc

Control Circuit Type

Dc Low Consumption

Protective Cover 

Yes

Usage Category

Ac-1

Ac-3

Ac-4

Power distribution per Pole

0.2 W Ac-3

1.56 W Ac-1

Fixing Pole Contact

3 Na

Pole Description

3P

Maximum Operating Rate

3600 Cyc/H -De <60 °C

Mechanical Durability

30 Mcycles

Montage Support

Plate Block

Rail

Motor Power Hp

For 0.33 Hp -De 115 V Ac 50/60 Hz 1 Phase Motors

For 1 Hp -De 230/240 V Ac 50/60 Hz 1 Phase Motors

For 2 Hp -De 200/208 V Ac 50/60 Hz 3 Phases Motors

For 2 Hp -De 230/240 V Ac 50/60 Hz 3 Phases Motors

For 5 Hp -De 460/480 V Ac 50/60 Hz 3 Phases Motors

For 7.5 Hp -De 575/600 V Ac 50/60 Hz 3 Phases Motors

Motor Power Kw

2.2 Kw -De 220...230 V Ac 50/60 Hz (Ac-3)

2.2 Kw -De 400 V Ac 50/60 Hz (Ac-4)

4 Kw -De 380...400 V Ac 50/60 Hz (Ac-3)

4 Kw -De 415...440 V Ac 50/60 Hz (Ac-3)

5.5 Kw -De 500 V Ac 50/60 Hz (Ac-3)

5.5 Kw -De 660...690 V Ac 50/60 Hz (Ac-3)

Rated Breaking Capacity 

250 A -De 440 V For Power Circuit 'E Conforming to Iec 60947

Average impedance

2.5 Mohm - Ith 25 A 50 Hz For Power Circuit

Series

Tesys

Tightening Torque

Power Circuit: 1.7 N.M - Above Screw Clamp Terminals - with Screwdriver flat Ø 6 Mm

Power Circuit: 1.7 N.M - Above Screw Clamp Terminals - with Screw Driver Philips No 2

Control Circuit: 1.7 N.M - Above Screw Clamp Terminals - with Screwdriver flat Ø 6 Mm

Control Circuit: 1.7 N.M - Above Screw Clamp Terminals - Screwdriver Philips No 2

Standarts

Csa C22.2 No 14

En 60947-4-1

En 60947-5-1

Iec 60947-4-1

Iec 60947-5-1

Ul 508

Product Name

Tesys D

Product Group

Lc1D

Product Series

Tesys D

Product Certificates

Bv

Ccc

Csa

Dnv

Gl

Gost

Lros (Lloyds Register Of Shipping)

Rına

Ul

Product or Unit Type

Contactor

Fixing Auxiliary Contact

1 Na + 1 Nk

Features

Flame Vetarder

V1 'E Conforming to Ul 94

Ambient Air Condition for Operating

-40-60 °C

60-70 °C with derating

Operating altitude

0...3000 M

Environmental Characteristic for Storage

-60-80 °C

Depth

95 Mm

Width

45 Mm

IP Protection Degree

Ip20 Front 'E Conforming to Iec 60529

Pollution Degree 

3

Preventive Maintenance

Th 'E Conforming to Iec 60068-2-30

Mechanical Robustness

Shocks Contactor Open: 11 Msn for 10 Gn

Shocks Contactor Close: 11 Msn for 15 Gn

Vibrations Contactor Open: 2 Gn, 5...300 Hz

Vibrations Contactor Close: 4 Gn, 5...300 Hz

Product Weight

0.48 Kg

Fire Endurance

850 °C 'E Conforming to IEC 60695-2-1

Heigh

77 Mm

General Features

Coil Technology

Built-in bidirectional peak limiting diode suppressor

Contactor Coil Voltage

24 V Dc Low Consumption

Non-overlapping time

In 1.5 Ms Blackout Power Between Nk Ve Na Contact

In 1.5 Ms Energization Between Nk Ve Na Contact

Power Range

1.1-2 Kw -De 200-240 V 3 Phase

2.2-3 Kw -De 380-440 V 3 Phase

4-6 Kw -De 380-440 V 3 Phase

4-6 Kw -De 480-500 V 3 Phase

Heat Distribution

2-3 W -De 50/60 Hz

Contact Compatibility

M4

Control Circuit Voltage Limits

0,1...0,3 Uc -40-70 °C Reduce Ac DC

0,8...1,25 Uc -40-60 °C Operating DC

1...1.25 Uc 60-70 °C Operating DC

Minimum Switching Current

For 5 Ma Signaling Circuit

Minimum Switching Voltage

For 17 V Signaling Circuiti

Motor Starter Type

Direct On-Line Contactor

Signaling Circuit Frequency

25...400 Hz

Compatibility Code

Lc1D

Inrush Power in W 

2.4-2.4 W 20 °C)

Hold Power Consumption in W 

2.4-2.4 W -De 20 °C

Insulation Resistance

For > 10 Mohm Signaling Circuit

Auxiliary Contact Type

Type is Mirror Contact 1 Nk 'E Conforming to IEC 60947-4-1

Type is connected as mechanical 1 Na + 1 Nk 'E Conforming to Iec 60947-5-1

Time Constant

40MS

Dimensions(cm)
9.199999809265137 x 11.199999809265137 x 5.199999809265137
Weight(Kg)
0.5400000214576721
Warranty
18