Out Of Stock
Notify me when its in stock|
Basic |
|
|
[Icw] Rated Short-Time Withstand Current |
100 A - 1 S for Signaling Circuit |
|
120 A 50 Ms Min For Signaling Circuit |
|
|
140 A -De <40 °C - 1 S For Signaling Circuit |
|
|
72 A -De <40 °C – 10 min For Power Circuit |
|
|
720 A -De <40 °C - 1 S For Power Circuit |
|
|
165 A -De <40 °C - 1 min For Power Circuit |
|
|
[Ie] Rated Operational Current |
For 40 A 60 °C) -De <= 440 V Ac Ac-3 Power Circuit |
|
For 60 A 60 °C) -De <= 440 V Ac Ac-3 Power Circuit |
|
|
[Ith] Classic Open Air Thermic Current |
For 10 A -De <60 °C Signaling Circuit |
|
60 A -De <60 °C Power Circuit |
|
|
[Ue] Rated Operational Voltage |
Power Circuit: <= 300 V DC |
|
Power Circuit: <= 690 V Ac 25...400 Hz |
|
|
Power Circuit: 600 V CSA certificated |
|
|
Power Circuit: 600 V UI certificated |
|
|
Signaling Circuit: 600 V UI certificated |
|
|
Signaling Circuit: 600 V CSA certificated |
|
|
Signaling Circuit: 690 V Conforming to IEC 60947-1 |
|
|
[Uimp] Rated Impulse Withstand Voltage |
6 Kv 'E Conforming to IEC 60947 |
|
Overvoltage Category |
Iıı |
|
Terminals |
Power Circuit: Screwed Terminals Cable(s) 1-35 Mm² flexible |
|
Power Circuit: Screwed Terminal Cable(s) 1-35 Mm² flexible Cable Jagless |
|
|
Power Circuit: Screwed Terminal 1 Cable(s) 1- 35Mm² Solid Cable Jagless |
|
|
Power Circuit: Screwed Terminals Cable(s) 1-25 Mm² flexible |
|
|
Power Circuit: Screwed Terminal 1 Cable(s) 1- 25Mm² flexible Cable Jagless |
|
|
Power Circuit: Screwed Terminal 1 Cable(s) 1- 25Mm² Solid Cable Jagless |
|
|
Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm² flexible |
|
|
Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm² flexible Cable Jagless |
|
|
Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm² Solid Cable Jagless |
|
|
Operating Time |
12…26 Msn Closing |
|
4…19 Msn Opening |
|
|
Electric Durability |
1.4 Mcycles 38 A Ac-1 Ue'De <= 440 V |
|
1.4 Mcycles 50 A Ac-1 Ue'De <= 440 V |
|
|
Level of Security Safety |
B10D = 1369863 Cycles Rated Load Contactor 'E Conforming to En/Iso 13849-1 |
|
B10D = 20000000 Cycles Mechanical Load Contactor 'E Conforming to En/Iso 13849-1 |
|
|
Irms Rated Closing Capacity |
For 550 A -De 440 V Power Circuit 'E Conforming to Iec 60947-5-1 |
|
For 250 A Dc Signaling Circuit 'E Conforming to Iec 60947-5-1 |
|
|
For 140 A Ac Signaling Circuit 'E Conforming to Iec 60947-5-1 |
|
|
Fuse Value |
For 80 A Gg -De <= 690 V Power Circuit for Coordination Type 2 |
|
80 A Gg -De <= 690 V Power Circuit for Coordination Type 2 |
|
|
For 10 A Gg Signaling Circuit 'E Conforming to Iec 60947-5-1 |
|
|
Contactor Application |
Resistor Load |
|
Motor Control |
|
|
Control Circuit Voltage |
48 V Ac 50/60 Hz |
|
Control Circuit Type |
Ac -De 50/60 Hz |
|
Protective Cover |
Yes |
|
Usage Category |
Ac-1 |
|
Ac-3 |
|
|
Ac-4 |
|
|
Power distribution per Pole |
2.4 W Ac-3 |
|
5.4 W Ac-1 |
|
|
Fixing Pole Contact |
3 Na |
|
Pole Description |
3P |
|
Maximum Operating Rate |
3600 Cyc/H -De <60 °C |
|
Mechanical Durability |
6 Mcycles |
|
Montage Support |
Plate Block |
|
Rail |
|
|
Rated Breaking Capacity |
800 A -De 440 V For Power Circuit 'E Conforming to Iec 60947 |
|
Motor Power HP |
10 Hp -De 200/208 V Ac 50/60 Hz For3 Phases Motors |
|
10 Hp -De 230/240 V Ac 50/60 Hz For3 Phases Motors |
|
|
3 Hp -De 115 V Ac 50/60 Hz For3 Phases Motors |
|
|
30 Hp -De 460/480 V Ac 50/60 Hz For3 Phases Motors |
|
|
30 Hp -De 575/600 V Ac 50/60 Hz For 3 Phases Motors |
|
|
5 Hp -De 230/240 V Ac 50/60 Hz For 1 Phases Motors |
|
|
Motor Power KW |
11 Kw -De 220...230 V Ac 50/60 Hz (Ac-3) |
|
18.5 Kw -De 380...400 V Ac 50/60 Hz (Ac-3) |
|
|
22 Kw -De 415...440 V Ac 50/60 Hz (Ac-3) |
|
|
22 Kw -De 500 V Ac 50/60 Hz (Ac-3) |
|
|
30 Kw -De 660...690 V Ac 50/60 Hz (Ac-3) |
|
|
9 Kw -De 400 V Ac 50/60 Hz (Ac-4) |
|
|
Average impedance |
1.5 Mohm - Ith 60 A 50 Hz For Power Curcuit |
|
Series |
Tesys |
|
Tightening Torque |
Power Circuit: 5 N.M - Above Everlink Btr Screwed Connector- Cable 1-25 Mm² Hexagon 4mm |
|
Power Circuit: 8 N.M - Above Everlink Btr Screwed Connector- Cable 25-35 Mm² Hexagon 4mm |
|
|
Control Circuit: 1.7 N.M - Above Screw Clamp Terminals - with Screw Driver Flat 6mm |
|
|
Control Circuit: 1.7 N.M - Above Screw Clamp Terminals - with Screwdriver Philips No 2 |
|
|
Standarts |
Csa C22.2 No 14 |
|
En 60947-4-1 |
|
|
En 60947-5-1 |
|
|
Iec 60947-4-1 |
|
|
Iec 60947-5-1 |
|
|
Ul 508 |
|
|
Product Name |
Tesys D |
|
Product Group |
Lc1D |
|
Product Series |
Tesys D |
|
Product Certificates |
Bv |
|
Ccc |
|
|
Csa |
|
|
Dnv |
|
|
Gl |
|
|
Gost |
|
|
Lros (Lloyds Register Of Shipping) |
|
|
Rına |
|
|
Ul |
|
|
Product or Unit Type |
Contactor |
|
Auxiliary Contact Fixing |
1 Na + 1 Nk |
|
Features |
|
|
Flame Vetarder |
V1 'E Conforming to Ul 94 |
|
Ambient Air Condition for Operating |
-40-60 °C |
|
60-70 °C with derating |
|
|
Operating altitude |
0...3000 M |
|
Environmental Characteristic for Storage |
-60-80 °C |
|
Depth |
120 Mm |
|
Width |
55 Mm |
|
IP Protection Degree |
Ip20 Front 'E Conforming to Iec 60529 |
|
Pollution Degree |
3 |
|
Preventive Maintenance |
Th 'E Conforming to Iec 60068-2-30 |
|
Mechanical Robustness |
Shocks Contactor Open: 11 Msn for 10 Gn |
|
Shocks Contactor Close: 11 Msn for 15 Gn |
|
|
Vibrations Contactor Open: 2 Gn, 5...300 Hz |
|
|
Vibrations Contactor Close: 4 Gn, 5...300 Hz |
|
|
Product Weight |
0.85 Kg |
|
Fire Endurance |
850 °C 'E Conforming to IEC 60695-2-1 |
|
Heigh |
122 Mm |
|
General Features |
|
|
Bobin Technology |
Without built-in suppressor module |
|
Contactor Coil Voltage |
48 V Ac Standart |
|
Heat Distrubition |
2-3 W -De 50/60 Hz |
|
Non-overlapping time |
In 1.5 Ms Blackout Power Between Nk and Na Contact |
|
In 1.5 Ms Energization Between Nk and Na Contact |
|
|
Contact Compatibility |
M2 |
|
Power Range |
15-25 Kw -De 380-440 V 3 Phases |
|
15-25 Kw -De 480-500 V 3 Phases |
|
|
7-11 Kw -De 200-240 V 3 Phases |
|
|
Control Circuit Voltage Limits |
0,3...0,6 Uc -40-70 °C Reduce Ac 50/60 Hz |
|
0,8...1,1 Uc -40-60 Operating Ac 50/60 Hz |
|
|
0,85...1,1 Uc -40-60 °C Operating Ac 60 Hz |
|
|
1...1.1 Uc 60-70 °C Operating Ac Ac 50/60 Hz |
|
|
Compatibility Code |
Lc1D |
|
Inrush Power in Va |
140-140 Va 60 Hz 0.75 20 °C) |
|
160-160 Va 50 Hz 0.75 20 °C) |
|
|
Hold Power Consumption in Va |
13-13 Va 60 Hz 0.3 20 °C) |
|
15-15 Va 50 Hz 0.3 20 °C) |
|
|
Minimum Switching Current |
For 5 Ma Signaling Circuit |
|
Minimum Switching Voltage |
For 17 V Signaling Circuit |
|
Motor Starter Type |
Direct On-Line Contactor |
|
Signaling Circuit Frequency |
25...400 Hz |
|
Auxiliary Contact Type |
Type is Mirror Contact 1 Nk 'E Conforming to IEC 60947-4-1 |
|
Type is connected as mechanical 1 Na + 1 Nk 'E Conforming to Iec 60947-5-1 |
|