[Icw] Rated Short-Time Withstand Current

100 A - 1 S for Signaling Circuit

120 A 50 Ms Min For Signaling Circuit

140 A -De <40 °C - 1 S For Signaling Circuit

84 A -De <40 °C - 10 min For Power Circuit

400 A -De <40 °C – 10 s For Power Circuit

810 A -De <40 °C - 1 S For Power Circuit

208 A -De <40 °C - 1 min For Power Circuit

[Ie] Rated Operational Current

For 50 A 60 °C) -De <= 440 V Ac Ac-3 Power Circuit

For 80 A 60 °C) -De <= 440 V Ac Ac-3 Power Circuit

[Ith] Classic Open Air Thermic Current

For 10 A -De <60 °C Signaling Circuit

80 A -De <60 °C Power Circuit

[Ue] Rated Operational Voltage

Power Circuit: <= 300 V DC

Power Circuit: <= 690 V Ac 25...400 Hz

Power Circuit: 600 V CSA certificated

Power Circuit: 600 V UI certificated

Signaling Circuit: 600 V UI certificated

Signaling Circuit: 600 V CSA certificated

Signaling Circuit: 690 V Conforming to IEC 60947-1

[Uimp] Rated Impulse Withstand Voltage

6 Kv 'E Conforming to IEC 60947

Overvoltage Category

Iıı

Terminals

Power Circuit: Everlink BTR Screwed Terminals Cable(s) 1-35 Mm² flexible 

Power Circuit: Everlink BTR Screwed Terminal Cable(s) 1-35 Mm² flexible Cable Jagless

Power Circuit: Everlink BTR Screwed Terminal 1 Cable(s) 1- 35Mm² Solid Cable Jagless

Power Circuit: Everlink BTR Screwed Terminals Cable(s) 2-25 Mm² flexible 

Power Circuit: Everlink BTR Screwed Terminal 1 Cable(s) 2- 25Mm² flexible Cable Jagless

Power Circuit: Everlink BTR Screwed Terminal 1 Cable(s) 2- 25Mm² Solid Cable Jagless

Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm² flexible 

Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm² flexible Cable Jagless

Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm² Solid Cable Jagless

Operating Time

12…26 Msn Closing

4…19 Msn Opening

Electric Durability

1.1 Mcycles 38 A Ac-1 Ue'De <= 440 V

1.45 Mcycles 50 A Ac-1 Ue'De <= 440 V

Level of Security Safety 

B10D = 1369863 Cycles Rated Load Contactor 'E Conforming to En/Iso 13849-1

B10D = 20000000 Cycles Mechanical Load Contactor 'E Conforming to En/Iso 13849-1

Irms Rated Closing Capacity

For 900 A -De 440 V Power Circuit 'E Conforming to Iec 60947-5-1

For 250 A Dc Signaling Circuit 'E Conforming to Iec 60947-5-1

For 140 A Ac Signaling Circuit 'E Conforming to Iec 60947-5-1

Fuse Value

For 100 A Gg -De <= 690 V Power Circuit for Coordination Type 2

100 A Gg -De <= 690 V Power Circuit for Coordination Type 2

For 10 A Gg Signaling Circuit 'E Conforming to Iec 60947-5-1

Contactor Application

Resistor Load

Motor Control

Control Circuit Voltage

220 V Ac 50/60 Hz

Control Circuit Type

Ac -De 50/60 Hz

Protective Cover 

Yes

Usage Category

Ac-1

Ac-3

Ac-4

Power distribution per Pole

3.7 W Ac-3

9.6 W Ac-1

Fixing Pole Contact

3 Na

Pole Description

3P

Maximum Operating Rate

3600 Cyc/H -De <60 °C

Mechanical Durability

6 Mcycles

Montage Support

Plate Block

Rail

Rated Breaking Capacity 

900 A -De 440 V For Power Circuit 'E Conforming to Iec 60947

Motor Power HP

15 Hp -De 200/208 V Ac 50/60 Hz For3 Phases Motors

15 Hp -De 230/240 V Ac 50/60 Hz For3 Phases Motors

3 Hp -De 115 V Ac 50/60 Hz For3 Phases Motors

40 Hp -De 460/480 V Ac 50/60 Hz For3 Phases Motors

40 Hp -De 575/600 V Ac 50/60 Hz For 3 Phases Motors

7.5 Hp -De 230/240 V Ac 50/60 Hz For 1 Phases Motors

Motor Power KW

11 Kw -De 400 V Ac 50/60 Hz (Ac-4)

15 Kw -De 220...230 V Ac 50/60 Hz (Ac-3)

22 Kw -De 380...400 V Ac 50/60 Hz (Ac-3)

25 Kw -De 415 V Ac 50/60 Hz (Ac-3)

30 Kw -De 440 V Ac 50/60 Hz (Ac-3)

30 Kw -De 500 V Ac 50/60 Hz (Ac-3)

Average impedance

1.5 Mohm - Ith 60 A 50 Hz For Power Curcuit

Series

Tesys

Tightening Torque

Power Circuit: 5 N.M - Above Everlink Btr Screwed Connector- Cable 1-25 Mm² Hexagon 4mm

Power Circuit: 8 N.M - Above Everlink Btr Screwed Connector- Cable 25-35 Mm² Hexagon 4mm

Control Circuit: 1.7 N.M - Above Screw Clamp Terminals - with Screw Driver Flat 6mm

Control Circuit: 1.7 N.M - Above Screw Clamp Terminals - with Screwdriver Philips No 2

Standarts

Csa C22.2 No 14

En 60947-4-1

En 60947-5-1

Iec 60947-4-1

Iec 60947-5-1

Ul 508

Product Name

Tesys D

Product Group

Lc1D

Product Series

Tesys D

Product Certificates

Bv

Ccc

Csa

Dnv

Gl

Gost

Lros (Lloyds Register Of Shipping)

Rına

Ul

Product or Unit Type

Contactor

Auxiliary Contact Fixing

1 Na + 1 Nk

Features

Flame Vetarder

V1 'E Conforming to Ul 94

Ambient Air Condition for Operating

-40-60 °C

60-70 °C with derating

Operating altitude

0...3000 M

Environmental Characteristic for Storage

-60-80 °C

Depth

120 Mm

Width

55 Mm

IP Protection Degree

Ip20 Front 'E Conforming to Iec 60529

Pollution Degree 

3

Preventive Maintenance

Th 'E Conforming to Iec 60068-2-30

Mechanical Robustness

Shocks Contactor Open: 11 Msn for 10 Gn

Shocks Contactor Close: 11 Msn for 15 Gn

Vibrations Contactor Open: 2 Gn, 5...300 Hz

Vibrations Contactor Close: 4 Gn, 5...300 Hz

Product Weight

0.855 Kg

Fire Endurance

850 °C 'E Conforming to IEC 60695-2-1

Heigh

122 Mm

General Features

Bobin Technology

Without built-in suppressor module

Contactor Coil Voltage

220 V Ac Standart

Heat Distrubition

4-5 W -De 50/60 Hz

Non-overlapping time

In 1.5 Ms Blackout Power Between Nk and Na Contact

In 1.5 Ms Energization Between Nk and Na Contact

Contact Compatibility

M2

Power Range

15-25 Kw -De 380-440 V 3 Phases

15-25 Kw -De 480-500 V 3 Phases

30-50 Kw -De 380-440 V 3 Phases

30-50 Kw -De 480-500 V 3 Phases

7-11 Kw -De 200-240 V 3 Phases

Control Circuit Voltage Limits

0,3...0,6 Uc -40-70 °C Reduce Ac 50/60 Hz

0,8...1,1 Uc -40-60 Operating Ac 50/60 Hz

0,85...1,1 Uc -40-60 °C Operating Ac 60 Hz

1...1.1 Uc 60-70 °C Operating Ac Ac 50/60 Hz

Compatibility Code

Lc1D

Inrush Power in Va 

140-140 Va 60 Hz 0.75 20 °C)

160-160 Va 50 Hz 0.75 20 °C)

 

Hold Power Consumption in Va 

13-13 Va 60 Hz 0.3 20 °C)

15-15 Va 50 Hz 0.3 20 °C)

Minimum Switching Current

For 5 Ma Signaling Circuit

Minimum Switching Voltage

For 17 V Signaling Circuit

Motor Starter Type

Direct On-Line Contactor

Signaling Circuit Frequency

25...400 Hz

Auxiliary Contact Type

Type is Mirror Contact 1 Nk 'E Conforming to IEC 60947-4-1

Type is connected as mechanical 1 Na + 1 Nk 'E Conforming to Iec 60947-5-1

 

Dimensions(cm)
13.5 x 15 x 6.2
Weight(Kg)
0.95
Warranty
18
Secure Payment System Your shopping is safe with 3D Security and 256 Bit SSL.