Schneider Electric TeSys D Contactor - 3P(3 NA) - AC-3 80A - 220V AC Coil

11,538.85 TL VAT 
9,615.71 TL + VAT
Money Order Price : 9,327.24 TL + VAT %3  Discount

Basic

[Icw] Rated Short-Time Withstand Current

100 A - 1 S for Signaling Circuit

120 A - 500 Ms for Signaling Circuit

135 A -De <40 °C - 10 min For Power Circuit

140 A - 100 Ms for Signaling Circuit

320 A -De <40 °C - 1 min For Power Circuit

640 A -De <40 °C - 10 s For Power Circuit

900 A -De <40 °C - 1S For Power Circuit

[Ie] Rated Operational Current

For 125 A 60 °C) -De <= 440 V Ac Ac-1 Power Circuit

For 80 A 60 °C) -De <= 440 V Ac Ac-3 Power Circuit

[Ith] Classic Open Air Thermic Current

For 10 A -De <60 °C Signaling Circuit

For 125 A -De <60 °C Power Circuit

[Ue] Rated Operational Voltage

Power Circuit: <= 300 V Ac 25...400 Hz

Power Circuit: <= 690 V Dc

 

 

[Ui] Rated Insulation Voltage

Power Circuit: 1000 V ‘EConforming toıec 60947-4-1

Power Circuit: 600 V CSA certificated

Power Circuit: 600 V UI certificated

Signaling Circuit: 600 V UI certificated

Signaling Circuit: 600 V CSA certificated

Signaling Circuit: 690 V Conforming to IEC 60947-1

[Uimp] Rated Impulse Withstand Voltage

8 Kv 'E Conforming to IEC 60947

Overvoltage Category

Iıı

Terminals

Power Circuit: Connector 1 Cable(s) 4-50 Mm²flexible 

Power Circuit: Connector 1 Cable(s) 4-50 Mm²flexible Cable Jagless

Power Circuit: Connector 1 Cable(s) 4-50 Mm²Solid Cable Jagless

Power Circuit : Connector 2 Cable(s) 4-16 Mm² flexible 

Power Circuit: Connector 2 Cable(s) 4-25 Mm² flexible Cable Jagless

Power Circuit: Connector 2 Cable(s) 4-25 Mm² Solid Cable Jagless

Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-2.5 Mm²flexible 

Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-4 Mm²flexible Cable Jagless

Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm²Solid Cable Jagless

Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-2.5 Mm²flexible 

Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-4 Mm²flexible Cable Jagless

Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-4 Mm²Solid Cable Jagless

Operating Time

20…35 Msn Closing

6…20 Msn Opening

Electric Durability

0.8 Mcycles 95 A Ac-3

1.5 Mcycles 125 A Ac-1

Level of Security Safety 

B10D = 1.3 Mcycles Cycles Rated Load Contactor 'E Conforming to En/Iso 13849-1

B10D = 20000000 Cycles Mechanical Load Contactor 'E Conforming to En/Iso 13849-1

Irms Rated Closing Capacity

For 1100 A -De 440 V Signaling Circuit 'E Conforming to Iec 60947-5-1

For 140 A Ac Power Circuit 'E Conforming to Iec 60947-5-1

For 250 A Dc Signaling Circuit 'E Conforming to Iec 60947-5-1

Fuse Value

For 10 A Gg Signaling Circuit 'E Conforming to Iec 60947-5-1

200 A Gg -De <= 690 V Power Circuit for Coordination Type 2

160 A Gg -De <= 690 V Power Circuit for Coordination Type 2

Contactor Application

Resistor Load

Motor Control

Control Circuit Voltage

220 V Ac 50/60 Hz

Control Circuit Type

Ac -De 50/60 Hz

Protective Cover 

Yes

Usage Category

Ac-1

Ac-3

Ac-4

Power distribution per Pole

12.5 W Ac-1

7.2 W Ac-3

Fixing Pole Contact

3 Na

Pole Description

3P

Maximum Operating Rate

3600 Cyc/H -De <60 °C

Mechanical Durability

4Mcycles

Montage Support

Plate Block

Rail

Rated Breaking Capacity 

1100 A -De 440 V For Power Circuit 'E Conforming to Iec 60947

Motor Power HP

15 Hp -De 230/240 V Ac 50/60 Hz for 1 Phase Motors

20Hp -De 200/208 V Ac 50/60 Hz for 3 Phase Motors

25 Hp -De 230/240 V Ac 50/60 Hz for 3 Phase Motors

60 Hp -De 460/480 V Ac 50/60 Hz for 3 Phase Motors

60 Hp -De 575/600 V Ac 50/60 Hz for 3 Phase Motors

7.5 Hp -De 115 V Ac 50/60 Hz for 3 Phase Motors

Motor Power KW

15 Kw -De 400 V Ac 50/60 Hz (Ac-4)

22 Kw -De 220...230 V Ac 50/60 Hz (Ac-3)

37 Kw -De 380...400 V Ac 50/60 Hz (Ac-3)

45 Kw -De 1000 V Ac 50/60 Hz (Ac-3)

45 Kw -De 415...440 V Ac 50/60 Hz (Ac-3)

45 Kw -De 660...690 V Ac 50/60 Hz (Ac-3)

55 Kw -De 500 V Ac 50/60 Hz (Ac-3)

Average impedance

0.8 Mohm - Ith 200 A 50 Hz For Power Circuit

Series

Tesys

Tightening Torque

Power Circuit: 12 N.M - Above Connector with Screw Driver Flat 6-8 MM

Power Circuit: 12 N.M - Above Connector Hexagon 4 Mm

Power Circuit: 1.2 N.M - Above Screw Clamp Terminals - with Screw Driver Flat 6 mm

Control Circuit: 1.2 N.M - Above Screw Clamp Terminals - with Screwdriver Philips No 2

Standarts

Csa C22.2 No 14

En 60947-4-1

En 60947-5-1

Iec 60947-4-1

Iec 60947-5-1

Ul 508

Product Name

Tesys D

Product Group

Lc1D

Product Series

Tesys D

Product Certificates

Bv

Ccc

Csa

Dnv

Gl

Gost

Lros (Lloyds Register Of Shipping)

Rına

Ul

Product or Unit Type

Contactor

Auxiliary Contact Fixing

1 Na + 1 Nk

Features

Flame Vetarder

V1 'E Conforming to Ul 94

Ambient Air Condition for Operating

-40-60 °C

60-70 °C with derating

Operating altitude

0...3000 M

Environmental Characteristic for Storage

-60-80 °C

Depth

130 Mm

Width

85 Mm

IP Protection Degree

Ip20 Front 'E Conforming to Iec 60529

Pollution Degree 

3

Preventive Maintenance

Th 'E Conforming to Iec 60068-2-30

Mechanical Robustness

Shocks Contactor Open: 11 Msn for 10 Gn

Shocks Contactor Close: 11 Msn for 15 Gn

Vibrations Contactor Open: 2 Gn, 5...300 Hz

Vibrations Contactor Close: 4 Gn, 5...300 Hz

Product Weight

1.59 Kg

Fire Endurance

850 °C 'E Conforming to IEC 60695-2-1

Heigh

127 Mm

General Features

Bobin Technology

Without built-in suppressor module

Contactor Coil Voltage

220 V Ac Standart

Heat Distrubition

6-10 W -De 50/60 Hz

Non-overlapping time

In 1.5 Ms Blackout Power Between Nk Ve Na Contact

In 1.5 Ms Energization Between Nk Ve Na Contact

Contact Compatibility

M11

Power Range

15-25 Kw -De 200-240 V 3 Phase

30-50 Kw -De 380-440 V 3 Phase

30-50 Kw -De 480-500 V 3 Phase

55-100 Kw -De 480-500 V 3 Phase

Control Circuit Voltage Limits

0,3...0,6 Uc -40-70 °C Reduce Ac 50/60 Hz

0,8...1,1 Uc -40-55 Operating Ac 50 Hz

0,85...1,1 Uc -40-55 Operating 60 Hz

1...1.1 Uc 55-70 °C Operating Ac Ac 50/60 Hz

Compatibility Code

Lc1D

Inrush Power in Va 

245-245 Va 50 Hz 0.75 20 °C)

245-245 Va 60 Hz 0.75 20 °C)

 

Hold Power Consumption in Va 

26-26 Va 50 Hz 0.3 20 °C)

26-26 Va 60 Hz 0.3 20 °C)

Minimum Switching Current

For 5 Ma Signaling Circuit

Minimum Switching Voltage

For 17 V Signaling Circuit

Motor Starter Type

Direct On-Line Contactor

Signaling Circuit Frequency

25...400 Hz

Auxiliary Contact Type

Type is Mirror Contact 1 Nk 'E Conforming to IEC 60947-4-1

Type is connected as mechanical 1 Na + 1 Nk 'E Conforming to Iec 60947-5-1

 

Dimensions(cm)
13.199999809265137 x 14 x 9.399999618530273
Weight(Kg)
1.559999942779541
Warranty
18
Secure Payment System Your shopping is safe with 3D Security and 256 Bit SSL.
Your shopping is safe with 3D Security and 256 Bit SSL.