Out Of Stock
Notify me when its in stock
Basic |
|
15 Ka -De 380 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
|
[Ics] Rated Service Breaking Capacity |
5 Ka -De 440 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
2.5 Ka -De 550 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
|
5 Ka -De 125 V Dc 'E Confirmation to IEC 60947-2 |
|
5 Ka -De 250 V Dc 'E Confirmation to IEC 60947-2 |
|
5 Ka -De 440 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
|
50 Ka -De 110/130 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
|
|
50 Ka -De 220/230/240 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
|
7.5 Ka -De 400/415 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
[In] Rated Current |
100 A -De 40 °C |
[Ue] Rated Operation Voltage |
250 V Dc Hz 'E Confirmation to IEC 60947-2 |
550 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
|
[Ui] Rated Insulation Voltage |
690 V Ac 50/60 Hz 'E Confirmation to 60947-2 |
[Uimp] Rated Impulse Withstand Voltage |
6 Kv 'E Confirmation to EN/Iec 60947-2 |
Trip Unit Name |
Tm-D |
Trip Unit Degree |
75-75 A -De 50 °C |
Trip Unit Technology |
Thermal Magnetic |
Device Application |
Distribution |
Degree Code |
H |
Circuit Breaker Name |
Easypact Ezcv250H |
Breaking Capacity |
10 Ka Icu -De 125 V Dc 1P 'E Confirmation to IEC 60947-2 |
10 Ka Icu -De 250 V Dc 2P 'E Confirmation to IEC 60947-2 |
|
10 Ka Icu -De 550 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
|
100 Ka Icu -De 110...130 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
|
100 Ka Icu -De 220...240 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
|
20 Ka Icu -De 440 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
|
30 Ka Icu -De 380 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
|
|
30 Ka Icu -De 400...415 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
Pollution Degree |
3 ‘E Confirmation to IEC 60947 |
|
3 'E Confirmation to IEC 947-1 |
Protection Type |
Overload Protection |
Short Circuit Protection |
|
Protective Pole Description |
3T |
Usage Category |
Category A |
Pole Description |
3P |
Series |
Easypact |
Network Frequency |
50/60 Hz |
Network Type |
Ac |
Dc |
|
Product Name |
Easypact Ezc |
Product Group |
Easypact Ezcv630H |
Product Series |
Easypact |
Product or Component Type |
Circuit Breaker |
Compatibility to Insulation |
Yes, ‘E Confirmation to IEC 60947-2 |
Classification |
|
Environment Condition for Storage |
-35-85 °C |
Ik Protection Degree |
Ik07 'E Confirmation to IEC 50102 |
Ip Protection Degree |
Ip20 'E Confirmation to IEC 60529 |
Pollution Degree |
3 'E Confirmation to IEC 60664-1 |
Rated Operation Environment Temperature |
-25-70 °C |
Standards |
En/Iec 60947-1 |
En/Iec 60947-2 |
|
Gb/T 14048.2 |
|
General Features |
|
Bottom Connection |
Front |
Connection Distance |
25 Mm |
Signalization on Device |
Positive Contact Signal |
Depth |
60 Mm |
Electrical Durability |
Category A: 5000 Cycles 415 V Ac 50/60 Hz 'E Confirmation to IEC 60947-2 |
Width |
75 Mm |
Control Type |
Transition |
Mechanical Durability |
8500 Cycles |
Montage Support |
Behind Plaque |
Montage Type |
Fixture |
Neutral Protection Adjustment |
No Protection (3D) |
Color |
Black |
Piece Per Set |
1 Piece |
Marketing Segment |
Small-size Enterprises |
Erath Leakage Protection |
None |
Compatibility Code |
Ezcv100 |
Top Connection |
Front |
Height |
130 Mm |